User Manual
User’s Manual of ICS-10x
-5-
LED indicators for easy network diagnose
Reset Button at the front panel for reset to factory default
1.6 PRODUCT SPECIFICATION
Products ICS-100 ICS-101 ICS-102 ICS-102S15 ICS-105A
Hardware Specification
Interface RS-232 / RS-422 / RS-485
Connector 3-in-1 DB9
Baud rate 300 to 921600bps
Character Bits 5,6,7,8
Parity type 1, 1.5/2
Stop Bit Odd, Even, None, Space, Mark
Flow Control H/W, None
Serial Port
Signals
RS-232: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422: Tx+, Tx-, Rx+, Rx-, GND
RS-485 (2-wire): Data+, Data-
RS-485 (4-wire): Tx+, Tx-, Rx+, Rx-
Standard
IEEE 802.3 Ethernet ,10Bas-T
IEEE 802.3u Fast Ethernet, 10/100Base-TX, 100Base-FX
Connector RJ-45 ST SC LC
Fiber Mode - Multi-Mode Single-Mode
Single-Mode
Multi-Mode
Transmission
Mode
Full-Duplex /
Half-Duple
Full-Duplex
Distance 100m 2km 15km Depend of SFP module
Ethernet Port
Optical
Wavelength
- 1300nm 1310nm Depend of SFP module
Cable Twisted-pair
50/125μm or 62.5/125μm
multi-mode fiber cable
9/125μm
single-mode cable
50 or 62.5/125μm
multi-mode fiber cable
9/125μm single-mode
cable
Protection Built-in 1.5KV magnetic isolation
LED Indicators
System: Power
TP or Fiber Port: Link / Active
Serial Port: Link / Active
Management
Web Management
PLANET VCOM Utility
PLANET Smart Discovery Utility
Operation Mode
TCP Server
TCP Client
UDP Client
Virtual COM
Telnet Server
Pair Connection – Remote (Slave)
Pair Connection – Local (Master)