1. Package Contents
Thank you for purchasing PLANET Industrial 5G NR Cellular
Gateway, ICG-2515 series. The descriptions of these models
are as follows
ICG-2515-NR
Industrial 5G NR Cellular Gateway with
5-Port 10/100/1000T
ICG-2515W-NR
Industrial 5G NR Cellular Wireless Gateway
with 5-Port 10/100/1000T
“Cellular Gateway” is used as an alternative name in this
Quick Installation Guide.
Open the box of the Cellular Gateway and carefully unpack
it. The box should contain the following items:
Industrial 5G NR Cellular Gateway x 1
Quick installation guide x 1
PLANET CloudViewer QIG x1
Wall-mount plate w/screw x 1 set
RJ45 dust cap x 6
5G NR antenna x 4
5G NR antenna extension with magnetic base x 4
Dual band Wi-Fi antenna x 2 (for ICG-2515W-NR)
Antenna dust cap x 4 (ICG-2515W-NR x 6)
If any item is found missing or damaged, please contact your
local reseller for replacement.
3. Hardware Installation
Refer to the illustration and follow the simple steps below to
quickly install your Cellular Gateway.
3.1 SIM Card Installation
A. Insert an ejector pin into the yellow button next to the tray
to loosen the tray.
SIM1
B. Pull out the tray gently from the tray slot. Place the SIM
card on the tray with the gold-colored contacts facing
upwards.
C. Insert the tray back into the tray slot.
2. Tighten the wire-clamp screws for preventing the wires from
loosening.
1 2 3 4 5 6
Power 1 Alarm Power 2
+ - + -
Note
The wire gauge for the terminal block should be in
the range between 12 and 24 AWG.
Note
PWR1 and PWR2 must provide the same DC
voltage while operating with dual power input.
3.3 Wi-Fi Antenna Installation
Step 1: Fasten the two dual-band antennas to the antenna
connectors on the front panel of the Cellular Gateway.
Step 2: Youcanbendtheantennastotyouractualneeds.
Two Wi-Fi
RP-SMA connectors
2. Requirements
Workstations running Windows 10/XP/2003/Vista/7/8/2008,
MAC OS X or later, Linux, UNIX, or other platforms are
compatible with TCP/IP protocols.
Workstations are installed with Ethernet NIC (Network Inter-
face Card).
Ethernet Port Connection
Network cables -- Use standard network (UTP) cables with
RJ45 connectors.
The above PC is installed with Web browser.
Note
It is recommended to use Internet Explorer 8.0 or
above to access the Cellular Gateway. If the Web
interface of the Cellular Gateway is not accessible,
please turn off the anti-virus software or firewall
and then try it again.
A mini SIM card with 5G NR and 4G LTE subscription
3.2 5G NR Antenna Installation
Step 1: Connect 5G NR antennas to the 5G NR antenna
extension.
Step 2: Fasten the 5G NR antenna extensions to the
connectors.
3.4 Wiring the Power Inputs
The 6-contact terminal block connector on the top panel
of Cellular Gateway is used for two redundant power inputs.
Please follow the steps below to insert the power wire.
Caution
When performing any of the procedures like
inserting the wires or tightening the wire-clamp
screws, make sure the power is OFF to prevent
from getting an electric shock.
1. Insert positive and negative DC power wires into contacts 1
and 2 for POWER 1, or 5 and 6 for POWER 2.
Max. Fault Alarm Loading: 24V, 1A
DI1 DO0 DO1DI0 GNDGND
ANT1 ANT3
ANT2
Cellular
ANT4
V1+ V2+
PWR1
PWR2Alarm
DC Input: 9-54V
, 1.5A max.
AC Input: 24V
, 0.5A max.
1 2 3 4 5 6
1 2 3 4 5 6
Note
Please make sure the input voltage is under the
specification of the Cellular Gateway.
3.5 Grounding the Device
User MUST complete grounding wired with the device;
otherwise, a sudden lightning could cause fatal damage to the
device. EMD (Lightning) DAMAGE IS NOT CONVERED UNDER
WARRANTY.
3.6 Wiring the Fault Alarm Contact
The fault alarm contacts are in the middle of the terminal block
connector as the picture shows below. Inserting the wires,
the Cellular Gateway will detect the fault status of the power
failure or port failure, and then will form an open circuit. The
following illustration shows an application example for wiring
the fault alarm contacts
Fault Alarm Contacts
The Fault Alarm Contacts are
energized (CLOSE) for normal
operation and will OPEN when
failure occurs
Alarm
Insert the wires into the fault alarm contacts
Note
1. The wire gauge for the terminal block should be
in the range between 12 and 24 AWG.
2. Alarm relay circuit accepts up to 24V (max.) and
1A current.