Quick Guide

7
Electric-lock Connector
1 2 3 4 5
1 2 3 4 5
S_IN S_OUT NC COM NO
Indoor switch Electric-lock switch
JP1 Jumper
There are two modes for power supply of electric-lock as shown in the picture
below.
Active Mode: When the electric-lock starting current is less than 12V/700mA,
please adjust the jumper to 1/2/3/4 pin (Default mode).
Passive Mode: When the electric-lock starting current is more than 12V/700mA,
please adjust the jumper to 2/3 pin.