0/100/1000Mbps Gigabit Ethernet Smart Swtich GSW-601S User’s Manaul
Trademarks Copyright PLANET Technology Corp. 2001. Contents subject to revision without prior notice. PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective owners. FCC Warning This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
TABLE OF CONTENTS 1. INTROUCTION .................................................................... 7 1.1 CHECKLIST ....................................................................... 7 1.2 ABOUT THE SWITCH .......................................................... 7 1.3 FEATURES ........................................................................ 8 1.4 SPECIFICATIONS ............................................................. 10 2. HARDWARE DESCRIPTION...........................................
A.1 SWITCH‘S RJ-45 PIN ASSIGNMENTS ............................... 35 A.2 10/100MBPS, 10/100BASE-TX ...................................... 35 A.3 RJ-45 CABLE PIN ASSIGNMENT........................................
This page intentionally left blank! GSW-601S User's Manual
1. INTROUCTION 1.1 Checklist Check the contents of your package for following parts: l l l l l GSW-601S. User's manual. Power cord. 19” rack mount brackets. RS-232 cable. If any of these pieces are missing or damaged, please contact your dealer immediately, if possible, retain the carton including the original packing material, and use them against to repack the product in case there is a need to return it to us for repair. 1.
In addition, the Switch is also support one module slot for 2 Gigabit Ethernet ports to uplink to a server or network backbone. These Switches are designed for Plug and Play installation, allows the network administrator to simply connect the network and power cables and the Switching/bridging functions begin automatically. The front panel of these Switches provide LEDs for easy recognition of the switch operation status and for troubleshooting.
w Support to handle up to 1522 bytes packet w LED indicators for simple diagnostics and management w Provide a reset switch in front panel w Internal power supply w Auto MDI/ MDI-X on each port w Smart function for advanced configuration: − Support one console port for switch configuration change, − Support per port Port-based VLAN and L2 Trunking with link redundancy, load balancing − Support four Class of Service (CoS) queues per egress port − Support per port setting, enabled/ disabled − Support port mi
1.4 Specifications Standard IEEE802.3, IEEE802.3u, IEEE802.3ab, IEEE802.3x 10Base-T,UTP/STP category 3 or 5 cable Network Media: 100Base-TX,UTP/STP category 5 cable 1000Base-T,UTP/STP category 5e cable, 4 pairs 1000Base-SX,Multi-mode 62.
2. HARDWARE DESCRIPTION This product series provide three different running speed – 10Mbps, 100Mbps, and 1000Mbps in the same switch and automatically distinguish the speed of incoming connection. This section describes the hardware features of these Switches. For easier management and control of the switch, familiarize yourself with its display indicators, and ports. Front panel illustrations in this chapter display the unit LED indicators.
GSW-2GT module front panel GSW-2SX module front panel LED indicators GSW-601S and GSW-2GT PWR Green Lit: Power on SMART Green Lit: CPU initial completed Lit: indicate link status and traffic 10/100/1000 Green Speed (10 for 10M, 100 for 100M, 1000 for 1000M) Lit: indicate data traffic status TX/ RX Green (TX for transmitting, RX for receiving) Lit: Full-Duplex FDX/ COL Green Blink: Half-Duplex/ Collision Off: Half-duplex or not connected GSW-2SX LINK Green Lit: indicate link status and traffic speed ACT Gr
2.2 Rear Panel The rear panel of the Switch indicates a AC inlet power socket, which accepts input power from 100 to 240VAC, 50-60Hz. And a RS-232 console port for setting up the switch via a connection to a terminal or PC using a terminal emulation program. Power Notice: 1. The device is a power-required device, it means, it will not work till it is powered. If your networks should active all the time, please consider using UPS (Uninterrupted Power Supply) for your device.
Make sure the wiring is correct It can be used Category 3/4/5 cable in 10 Mbps operation. To reliably operate your network at 100Mbps and 1000Mbps, you must use an Unshielded Twisted-Pair (UTP) Category 5 cable, or better Data Grade cabling. While a Category 3 or 4 cable may initially seem to work, it will soon cause data loss. 2.3.
Link/Speed LED Green Color 10/100/1000 Label Function The LED light up steadily to indicate the transmitting speed light up steadily to indicate link up at speed 10 10M light up steadily to indicate link up at speed 100 100M Light up steadily to indicate link up at speed 1000 1000M Full/ Half Duplex and Collision LED Green Color FDX / COL Label Function: The indicator LED flash up whenever there is a collision between a directly attached end node and any other node, and light up steadily for Full-duplex mod
This page intentionally left blank! 16 PLANET NOVASwitch series
3.CONFIGURATION 3.1 CONNECT TO PC RS-232 serial cable Prepare a RS-232 serial cable. Attach the 9-pin female connector to the male connector on the switch. Plug the other side of this cable to your PC.
3.2 Main Menu Launch the new terminal you just set up, and then, turn on the switch. See the following messages for successful connection. PLANET GSW-601S Gigabit Ethernet Smart Switch Configuration menu [ver. :x.xx] (0) Port Setting (1) VLAN (2) Trunk Port (3) Aging Control (4) Port Enable/Disable (5) Port Mirroring (6) Port-base priority (7) Mac address filter (8) Change password (9) Restore to Factory Default Select :>> To enter any of the submenus, simply type the number on the command line.
3.3 Submenu: (0) Port Setting [Port Setting] [1] [2] [3] [4] [5] [6] [7] [8] Auto Neg. O Speed Duplex O O O O O O O 1000 1000 1000 1000 1000 1000 1000 1000 F F F F F F F F Flow Control O O O O O O O O [Tab] : Move to next item [Space Bar] : Toggle item [S] : Save & Exit [Q] : Quit [U]:Up, [L]:Left [D]:Down, [R]:Right Use Tab or “U”,”D”,”L”,”R” to move the item which to be change, press space bar to change it, ”S” for save this configuration.
3.
3.5 Submenu: (2) TRUNK [TRUNK] [1] [2] [3] [4] [5] [6] [7] [8] [GROUP 1] x x x x x x x x [GROUP 2] x x x x x x x x [GROUP 3] x x x x x x x x [GROUP 4] x x x x x x x x member port of trunk group must belong to same VLAN [Tab] : Move to next item [Space Bar] : Toggle item [S] : Save & Exit [Q] : Quit [U]:Up, [L]:Left [D]:Down, [R]:Right Oà enables the port you select Xà disables the port you select Trunk port members must belong to same VLAN group.
3.
3.
3.
3.9 Submenu: (6) Port-base Priority [Port -base priority] [1] [2] [3] [4] [5] [6] [7] [8] level T T T T T T T T / T : the priority depend on 802.
3.
3.11 Submenu: (8) Change password / 6 characters max. / / Enter key to delete password / new password : ***** reconfirm : ***** User can set password for security, press enter key to disable password checking when system boot. 3.12 Submenu: (9) Restore to Factory Default This item will restore configuration to such setting 1. Port with auto-negotiation, 1000M, full duplex, flow-control enables 2. All ports assigned to one VLAN 3. Disable trunk setting 4.
This page intentionally left blank! 28 PLANET NOVASwitch series
4 SWITCH OPERATION 4.1 Address Table The Switch is implemented with an address table. This address table composed of many entries. Each entry is used to store the address information of some node in network, including MAC address, port no, etc. This information comes from the learning process of Ethernet Switch. 4.2 Learning When one packet comes in from any port, the Switch will record the source address, port no. and the other related information in address table.
4.4 Store-and-Forward Store-and-Forward is one type of packet-forwarding techniques. A Store-and Forward Ethernet Switching stores the incoming frame in an internal buffer, do the complete error checking before transmission. Therefore, no error packets occurrence, it is the best choice when a network needs efficiency and stability. The Ethernet Switch scans the destination address from the packet-header, searches the routing table provided for the incoming port and forwards the packet, only if required.
4.4 Auto-Negotiation The STP ports on the Switch have built-in “Auto-negotiation”. This technology automatically sets the best possible bandwidth when a connection is established with another network device (usually at Power On or Reset). This is done by detect the modes and speeds at the second of both device is connected and capable of, Both 10Base-T and 100Base-TX devices can connect with the port in either Half- or Full-Duplex mode. 1000Base-T and 1000Base-SX can only connected in Full-duplex mode.
This page intentionally left blank! 32 PLANET NOVASwitch series
5. TROUBLESHOOTING This chapter contains information to help you solve problems. If Giga Switch is not functioning properly, make sure the Ethernet Switch was set up according to instructions in this manual. The Link LED is not lit Solution: Check the cable connection and remove duplex mode of the Giga Switch Some stations can not talk to other stations located on The other port Solution: The address table may contain older information than of the address table of that node.
This page intentionally left blank! 34 PLANET NOVASwitch series
APPENDIX A A.1 Switch‘s RJ-45 Pin Assignments 1000Mbps,1000Base T Contact MDI MDI-X 1 BI_DA+ BI_DB+ 2 BI_DA- BI_DB- 3 BI_DB+ BI_DA+ 4 BI_DC+ BI_DD+ 5 BI_DC- BI_DD- 6 BI_DB- BI_DA- 7 BI_DD+ BI_DC+ 8 BI_DD- BI_DC- Implicit implementation of the crossover function within a twisted-pair cable, or at a wiring panel, while not expressly forbidden, is beyond the scope of this standard. A.
A.
EM-GSW6V1 ISO9002