2.2.5 Removing Redundant Power Supply
Follow these steps to remove the redundant power supply from the switch:
1. Press power eject button for 5-10 seconds to activate power swapping function.
2. When eject LED blinks 3 times in green, it means operation of power swapping is activated.
3. Then eject LED blinks in red, it means system’s PoE output is decreasing or less than the minimum threshold.
4. Then when eject LED indicator is in green for 20 seconds, it means system is ready for removing power supply.
5. Remove AC power cord from the PWR-CRPS power.
6. To remove the redundant power from the GS-6322-24P4X, press and hold the blue lever to the left till it is totally pulled out
from the power supply unit.
7. After PWR-CRPS power is removed, the eject LED will blink 2 times in green.
Figure 2-2-9 power eject button