User's Manual

Table Of Contents
Users Manual of GS-6322 Managed Switch Series
113
4.2.6.1 Power Configuration
You can use the Web managmenet interface and then System > Power Management > Power Configuration to change the
power configuration.
This page offers many options for you to manage power applications. This page displays power configuration screen in Figure
4-2-6-1 appears.
Figure 4-2-6-1: Power Configuration Screenshot
The page includes the following fields:
Object Description
Power Module
Operation Mode
The Managed Switch allows users to configure power module operation mode via
software setting to handle the demands of power redundancy or additional power
to PoE++ ports as needed.
RPS mode: Provides 1+1 power redundancy when two PSUs are installed.
Power budget is the same as that of one PSU
EPS mode: Provides double power budget by combining two PSUs to share
the maximum power budget.
Default setting: EPS mode
Number of PSUs
Displays the current number of operating PSUs(Power Supply Uint) that is
installed into the power module slot.
The value is 1 or 2
Effective Number of
PSUs
The effective number of PSUs, taking the 1+1 power redundancy feature into
account.
PSU Status
Displays the PSU status of Slot 1 and Slot 2, which can be one of the following:
Operational: The PSU is connected and works properly.
Not Present: The PSU is not present.
Not powered: The PSU is present but not connected to the power source.