Quick Guide

14
6. Power Operation Mode Management
The GS-6322-24P4X is designed with two extractive modular power supply slots
to support Redundant Power Supply (RPS) mode or Extended Power Supply
(EPS) mode via software setting to handle the demands of power redundancy or
additionalpowertoPoE++portsasneeded.
z RPS (1+1) mode: Where critical services are supported by PoE application,
the secondary PSU is needed to provide backup power in the event of a power
outage.
z EPS (2+0) mode: Where more PoE budget is required to support complete
application, the secondary PSU can provide additional PoE power. The two PSUs
combinedareabletoprovideamaximumoftotalPoEpower.
Userscanchooseoneordualpowersupplieswiththeinitialinstallation.
PowerModule
OperationMode
PoEBudgetwith
One1200WPSU
PoEBudgetwith
Two1200WPSUs
Power
Redundancy
RPSmode(1+1) 1000W 1000W Yes
EPSmode(2+0) 1000W 2200W -
Exampleonpowersupply:PWR-CRPS1200
Thefactorydefaultpowercongurationsareshownasfollows.
DefaultPowerModuleOperationMode:RPS
You can use the Web management interface and then System > Power
Managementtochangethepowerconguration.