Datasheet
4
GS-6322-24P4X
– SSHv2, TLSv1.2, SSL and SNMP v3 secure access
• SNMP Management
– Four RMON groups (history, statistics, alarms and events)
– SNMP trap for interface Link Up and Link Down
notication
• IPv6 IP address/NTP/DNS management
• Built-in Trivial File Transfer Protocol (TFTP) client
• BOOTP and DHCP for IP address assignment
• System Maintenance
– Firmware upload/download via HTTP/TFTP
– Reset button for system reboot or reset to factory default
– Dual images
• DHCP Relay and DHCP Option 82
• DHCP Server
• User Privilege levels control
• NTP (Network Time Protocol)
• Network Diagnostic
– SFP-DDM (Digital Diagnostic Monitor)
– ICMPv6/ICMPv4 remote ping
– Cable diagnostic technology provides the mechanism to
detect and report potential cabling issues
• SMTP/Syslog remote alarm
• System Log
• PLANET Smart Discovery Utility for deployment
management
• Smart fan with speed control
Power Management
• Dual redundant modular power supply slots
• Supportscongurablepoweroperationmodes
– RedundantPowerSupply(RPS,1+1):Provides1+1
power redundancy when two PSUs are installed.
– ExtendedPowerSupply(EPS,2+0):Providesmore
power budget by combining two PSUs to share the
maximum power budget
• Active-active redundant power failure protection
• Backup of catastrophic power failure on one supply
• Fault tolerance and resilience
Built-in Unique PoE Functions for Powered Devices Management
Being the managed PoE switch for surveillance, wireless and VoIP networks, the
GS-6322-24P4XfeaturesthefollowingspecialPoEmanagementfunctions:
■PDalivecheck
■Scheduledpowerrecycling
■PoEschedule
■PoEusagemonitoring
Intelligent Powered Device Alive Check
TheGS-6322-24P4XcanbeconguredtomonitorconnectedPD(powereddevice)
status in real time via ping action. Once the PD stops working and responding, the
GS-6322-24P4X will resume the PoE port power and bring the PD back to work. It
will greatly enhance the network reliability through the PoE port resetting the PD’s
power source and reducing administrator management burden.
PT PoE Camera
Ping Request
Ping Request
Check alive status for 3 times
Restart PoE device if without response
Ping Echo
No Response......
PD Alive!!
Step 1
Step 3
Step 2
Step 4
ON
PoE
ON
ON
PoE
OFF
PD Status
Good!!
Alarm Notification
Scheduled Power Recycling
The GS-6322-24P4X allows each of the connected PoE IP cameras or PoE wireless
access points to reboot at a specified time each week. Therefore, they will reduce
thechanceofIPcameraorAPcrashresultingfrombufferoverow.
S M T W T F S
Automatically Reboot
Every Friday 23:00
PoE PT Camera
ON ON
PoE
OFF
CPU/Buffer
Load 85%
CPU/Buffer
Load 10%
PoE Schedule for Energy Savings
Under the trend of energy savings worldwide and contributing to environmental
protection, the GS-6322-24P4X can effectively control the power supply besides
their capability of giving high watts power. The “PoE schedule” function helps you
to enable or disable PoE power feeding for each PoE port during specified time