GS-5220-Series (V4) User Manual

Table Of Contents
Users Manual of GS-5220 PoE Series Managed Switch
53
DC Power Connector
The following GS-5220 PoE series supports redundant power system (PoE not included ):
GS-5220-24P4XR
GS-5220-24PL4XR
GS-5220-48PL4XR
GS-5220-16UP4S2XR
GS-5220-24UP4XR
GS-5220-24UPL4XR
The rear panels of the above models have a power switch and a DC power connector, where the latter accepts DC power
input voltage from 36V to 60V DC. Connect the power cable to the Managed Switch at the input terminal block. The size of
the two screws in the terminal block is M3.5.
Figure 2-1-34: Rear Panel of GS-5220 PoE series Redundant Power Models
Warning:
Before connecting the DC power cable to the input terminal block of the GS-
5220 PoE series redundant
power models, make sure that the power switch is in the OFFposition and the DC power is OFF.