Users Manual of GS-5220 PoE Series Managed Switch
421
Buttons
: Click to reboot the system.
: Click to return to the Port State page without rebooting the system.
You can also check the SYS LED on
the front panel to identify whether the System is loaded completely or
not. If the SYS LED is blinking, then it is in the firmware load stage; if the SYS LED light is on, you can use
the Web browser to login the Managed Switch.
4.10.10 Ping
This page allows you to issue ICMP PING packets to troubleshoot IP connectivity issues.
After you pressStart, 5 ICMP packets are transmitted, and the sequence number and roundtrip time are displayed upon
reception of a reply. The page refreshes automatically until responses to all packets are received, or until a timeout occurs. The
ICMP Ping screen in Figure 4-10-10-1 appears.
Figure 4-10-10-1: ICMP Ping Page Screenshot
The page includes the following fields:
Object Description
IP Address
The destination IP Address.
Ping Length
The payload size of the ICMP packet. Values range from 2 bytes to 1452 bytes.