GS-5220-Series (V4) User Manual
Table Of Contents
- 1. INTRODUCTION
- 2. INSTALLATION
- 3. SWITCH MANAGEMENT
- 4. WEB CONFIGURATION
- 4.1 Main Web Page
- 4.2 System
- 4.2.1 Management
- 4.2.1.1 System Information
- 4.2.1.2 IP Configuration
- 4.2.1.3 IP Status
- 4.2.1.4 Users Configuration
- 4.2.1.5 Privilege Levels
- 4.2.1.6 NTP Configuration
- 4.2.1.6.1 System Time Correction Manually
- 4.2.1.7 Time Configuration
- 4.2.1.8 UPnP
- 4.2.1.9 DHCP Relay
- 4.2.1.10 DHCP Relay Statistics
- 4.2.1.11 CPU Load
- 4.2.1.12 System Log
- 4.2.1.13 Detailed Log
- 4.2.1.14 Remote Syslog
- 4.2.1.15 SMTP Configuration
- 4.2.2 Simple Network Management Protocol
- 4.2.3 RMON
- 4.2.4 DHCP server
- 4.2.1 Management
- 4.3 Switching
- 4.3.1 Port Management
- 4.3.2 Link Aggregation
- 4.3.3 VLAN
- 4.3.3.1 VLAN Overview
- 4.3.3.2 IEEE 802.1Q VLAN
- 4.3.3.3 VLAN Port Configuration
- 4.3.3.4 VLAN Membership Status
- 4.3.3.5 VLAN Port Status
- 4.3.3.6 Private VLAN
- 4.3.3.7 Port Isolation
- 4.3.3.8 VLAN setting example:
- 4.3.3.8.1 Two Separate 802.1Q VLANs
- 4.3.3.8.2 VLAN Trunking between two 802.1Q aware switches
- 4.3.3.8.3 Port Isolate
- 4.3.3.9 MAC-based VLAN
- 4.3.3.10 Protocol-based VLAN
- 4.3.3.11 Protocol-based VLAN Membership
- 4.3.4 Spanning Tree Protocol
- 4.3.5 IGMP Snooping
- 4.3.6 MLD Snooping
- 4.3.7 MVR (Multicast VLAN Registration)
- 4.3.8 LLDP
- 4.3.9 MAC Address Table
- 4.3.10 Loop Protection
- 4.3.11 UDLD
- 4.3.12 GVRP
- 4.3.13 Link OAM
- 4.4 Routing
- 4.5 Quality of Service
- 4.6 Security
- 4.7 Power over Ethernet
- 4.8 Ring
- 4.9 ONVIF
- 4.10 Maintenance
- 5. SWITCH OPERATION
- 6. TROUBLESHOOTING
- APPENDIX A: Networking Connection
- APPENDIX B : GLOSSARY
User’s Manual of GS-5220 PoE Series Managed Switch
404
Instance Configuration:
Object Description
• Configuration
Red: This ERPS is only created and has not yet been configured - is not active.
Green: This ERPS is configured - is active.
• Guard Time
Guard timeout value to be used to prevent ring nodes from receiving outdated
R-APS messages.
The period of the guard timer can be configured in 10 ms steps between 10 ms
and 2 seconds, with a default value of 500 ms
• WTR Time
The Wait To Restore timing value to be used in revertive switching.
The period of the WTR time can be configured by the operator in 1 minute steps
between 5 and 12 minutes with a default value of 5 minutes.
• Hold Off Time
The timing value to be used to make persistent check on Signal Fail before
switching.
The range of the hold off timer is 0 to 10 seconds in steps of 100 ms
• Version
ERPS Protocol Version - v1 or v2
• Revertive
In Revertive mode, after the conditions causing a protection switch has cleared,
the traffic channel is restored to the working transport entity, i.e., blocked on the
RPL.
In Non-Revertive mode, the traffic channel continues to use the RPL, if it is not
failed, after a protection switch condition has cleared.
• VLAN Config
VLAN configuration of the Protection Group. Click on the "VLAN Config" link to
configure VLANs for this protection group.
PRL Configuration:
Object Description
• PRL Role
It can be either RPL owner or RPL Neighbor.
• PRL Port
This allows to select the east port or west port as the RPL block.
• Clear
If the owner has to be changed, then the clear check box allows to clear the RPL
owner for that ERPS ring.