Hello Interval The time interval (in seconds) between hello packets. The allowed range is 1 to 65535 and the
default value is 10 (seconds).
Dead Interval The number of seconds to wait until the neighbour is decalred to be dead. The allowed range is 1
to 65535 and the default value is 40 (seconds).
Retransmit Interval The time interval (in seconds) between link-state advertisement(LSA) retransmissions for
adjacencies. The allowed range is 1 to 65535 and the default value is 5 (seconds).
Auth. Type The authentication type on an area.
Simple Password: It's using a plain text authentication. A password must be configured, but the
password can be read by sniffer the packets.
Message Digest: It's message-digest algorithm 5 (MD5) authentication. Keying material must
also be configured. This is the most secure method.
Null Authentication: No authentication.
Area Configuration: Refer to Area authentication setting.
Change Simple
Password
It is used to change the simple password (fill with plain text). The allowed input length is 1 to 8.
MD Key Click the icon to edit the message digest key for the entry.