User's Manual

Table Of Contents
Users Manual of GS-5220 PoE Series Managed Switch
264
default value is 10 (seconds).
Dead Interval The number of seconds to wait until the neighbour is decalred to be dead. The allowed range is 1
to 65535 and the default value is 40 (seconds).
Retransmit Interval The time interval (in seconds) between link-state advertisement(LSA) retransmissions for
adjacencies. The allowed range is 1 to 65535 and the default value is 5 (seconds).
Auth. Type The authentication type on an area.
Simple Password: It's using a plain text authentication. A password must be configured, but the
password can be read by sniffer the packets.
Message Digest: It's message-digest algorithm 5 (MD5) authentication. Keying material must
also be configured. This is the most secure method.
Null Authentication: No authentication.
Area Configuration
: Refer to Area authentication setting.
Change Simple
Password
It is used to change the simple password (fill with plain text). The allowed input length is 1 to 8.
MD Key Click the icon to edit the message digest key for the entry.
Buttons
Click to add new entry.
Click to save changes.
: Click to undo any changes made locally and revert to previously saved values.