User's Manual
Table Of Contents
- 1. INTRODUCTION
- 2. INSTALLATION
- 3. SWITCH MANAGEMENT
- 4. WEB CONFIGURATION
- 4.1 Main Web Page
- 4.2 System
- 4.2.1 Management
- 4.2.1.1 System Information
- 4.2.1.2 IP Configuration
- 4.2.1.3 IP Status
- 4.2.1.4 Users Configuration
- 4.2.1.5 Privilege Levels
- 4.2.1.6 NTP Configuration
- 4.2.1.6.1 System Time Correction Manually
- 4.2.1.7 Time Configuration
- 4.2.1.8 UPnP
- 4.2.1.9 DHCP Relay
- 4.2.1.10 DHCP Relay Statistics
- 4.2.1.11 CPU Load
- 4.2.1.12 System Log
- 4.2.1.13 Detailed Log
- 4.2.1.14 Remote Syslog
- 4.2.1.15 SMTP Configuration
- 4.2.2 Simple Network Management Protocol
- 4.2.3 RMON
- 4.2.4 DHCP server
- 4.2.5 LCD
- 4.2.1 Management
- 4.3 Switching
- 4.3.1 Port Management
- 4.3.2 Link Aggregation
- 4.3.3 VLAN
- 4.3.3.1 VLAN Overview
- 4.3.3.2 IEEE 802.1Q VLAN
- 4.3.3.3 VLAN Port Configuration
- 4.3.3.4 VLAN Membership Status
- 4.3.3.5 VLAN Port Status
- 4.3.3.6 Port Isolation
- 4.3.3.7 VLAN setting example:
- 4.3.3.7.1 Two Separate 802.1Q VLANs
- 4.3.3.7.2 VLAN Trunking between two 802.1Q aware switches
- 4.3.3.7.3 Port Isolate
- 4.3.3.8 MAC-based VLAN
- 4.3.3.9 Protocol-based VLAN
- 4.3.3.10 Protocol-based VLAN Membership
- 4.3.4 Spanning Tree Protocol
- 4.3.5 Multicast
- 4.3.6 MLD Snooping
- 4.3.7 MVR (Multicast VLAN Registration)
- 4.3.8 LLDP
- 4.3.9 MAC Address Table
- 4.3.10 Loop Protection
- 4.3.11 UDLD
- 4.3.12 GVRP
- 4.4 Quality of Service
- 4.5 Security
- 4.6 Ring
- 4.7 Maintenance
- 5. SWITCH OPERATION
- 6. TROUBLESHOOTING
- APPENDIX A: Networking Connection
- APPENDIX B : GLOSSARY
User’s Manual of GS-5220-16T2XV(R) Managed LCD Switch
269
■ Multi 802.1X
■ MAC-based Auth.
Direction Name IEEE Name Description
Rx Access
Challenges
dot1xAuthBackendAcce
ssChallenges
802.1X-based:
Counts the number of times
that the switch receives the
first request from the backend
server following the first
response from the supplicant.
Indicates that the backend
server has communication
with the switch.
MAC-based:
Counts all Access Challenges
received from the backend
server for this port (left-most
table) or client (right-most
table).
Rx Other
Requests
dot1xAuthBackendOther
RequestsToSupplicant
802.1X-based:
Counts the number of times
that the switch sends an EAP
Request packet following the
first to the supplicant.
Indicates that the backend
server chose an EAP-method.
MAC-based:
Not applicable.
Rx Auth.
Successes
dot1xAuthBackendAuth
Successes
802.1X- and MAC-based:
Counts the number of times
that the switch receives a
success indication. Indicates
that the supplicant/client has
successfully authenticated to
the backend server.
Rx Auth.
Failures
dot1xAuthBackendAuth
Fails
802.1X- and MAC-based:
Counts the number of times
that the switch receives a
failure message. This