User Guide

Table Of Contents
Command Guide of GS-5220-16S8C and GS-5220-16S8CR
Default:
Keep
Usage Guide:
To reset Delay Measurement of MEP while overflowing
Example:
To reset Delay Measurement of MEP 1 while overflowing
Switch# configure terminal
Switch (config)# mep 1 dm overflow-reset
4.2.131 mep <Instance> dm proprietary
Command:
mep <Instance> dm proprietary
mep Maintenance Entity Point
<Instance> The MEP instance number.
dm Delay Measurement
proprietary Proprietary Delay Measurement
Default:
Standard
Usage Guide:
To configure Tx mode (proprietary) of MEP.
Example:
To configure Tx mode (proprietary) of MEP 1
Switch# configure terminal
Switch (config)# mep 1 dm proprietary
4.2.132 mep <Instance> dm syncronized
Command:
mep <Instance> dm syncronized
mep Maintenance Entity Point
<Instance> The MEP instance number.
dm Delay Measurement
syncronized Near enad and far end is real time syncronized.
-245
-