User Guide

Table Of Contents
Command Guide of GS-5220-16S8C and GS-5220-16S8CR
To enable DSCP Classification of QoS for GigabitEthernet X/X
Switch# configure terminal
Switch (config)# interface GigabitEthernet X/X
Switch (config-if) # qos trust dscp
4.2.65.108 qos trust tag
Command:
qos trust tag
qos Quality of Service
trust Trust configuration
tag VLAN tag
Default:
Disabled
Usage Guide:
To enable VLAN tag Classification of QoS for specific interface
Example:
To enable VLAN tag Classification of QoS for GigabitEthernet X/X
Switch# configure terminal
Switch (config)# interface GigabitEthernet X/X
Switch (config-if) # qos trust tag
4.2.65.109 rmon collection history
Command:
rmon collection history <1-65535> buckets <1-65535> interval <1-3600>
rmon Configure Remote Monitoring on an interface
collection Configure Remote Monitoring Collection on an interface
history Configure history
buckets Requested buckets of intervals. Default is 50 buckets
interval Interval to sample data for each bucket. Default is 1800 seconds
Default:
N/A
-152
-