User Guide

Table Of Contents
Command Guide of GS-5220-16S8C and GS-5220-16S8CR
Switch (config)# interface GigabitEthernet X/X
Switch (config-if) # poe pdcheck interval 100
4.2.65.78 poe pdcheck reboot-time
Command:
poe pdcheck reboot-time <30-180>
poe Power Over Ethernet.
pdcheck Allows user to enable or disable per port PD Alive Check function.
reboot-time set the PoE device rebooting time.
<30-180> reboot-time <30-180>
Default:
90
Usage Guide:
To configure PD Ping Alive Check rebooting time of PoE for specific interface.
Example:
To configure PD Ping Alive Check rebooting time (100 seconds) of PoE for GigabitEthernet X/X.
Switch# configure terminal
Switch (config)# interface GigabitEthernet X/X
Switch (config-if) # poe pdcheck reboot-time 100
4.2.65.79 poe pdcheck retry-count
Command:
poe pdcheck retry-count <1-5>
poe Power Over Ethernet.
pdcheck Allows user to enable or disable per port PD Alive Check function.
retry-count set how many times system retry ping to PD.
<1-5> retry-count <1-5>
Default:
2
Usage Guide:
To configure PD Ping Alive Check retry count of PoE for specific interface.
-135
-