User's Manual

Table Of Contents
User’s Manual of GS-4210-16T2S_24T2S_24P2S
26
Console Port
The console port is a RJ45 port connector. It is an interface for connecting a terminal directly. Through the console port, it
provides rich diagnostic information including IP Address setting, factory reset, port management, link status and system
setting. Users can use the attached DB9 to RJ45 console cable in the package and connect to the console port on the
device. After the connection, users can run any terminal emulation program (Hyper Terminal, ProComm Plus, Telix,
Winterm and so on) to enter the startup screen of the device.
Reset Button
In the middle of the front panel, the reset button is designed for rebooting the Managed Switch without turning off and on the
power. The following is the summary table of Reset button function:
Reset Button Pressed and Released Function
> 5 seconds: Factory Default
Reset the Managed Switch to Factory Default configuration.
The Managed Switch will then reboot and load the default
settings as shown below:
Default Username: admin
Default Password: admin
Default IP address: 192.168.0.100
Subnet mask: 255.255.255.0
Default Gateway: 192.168.0.254
2.1.2 LED Indications
The front panel LEDs indicate instant status of port links, data activity, PoE status and system power; helps monitor and
troubleshoot when needed. Figure 2-1-4, Figure 2-1-5 and Figure 2-1-6 show their LED indications.
LED Indication
Figure 2-1-4: GS-4210-16T2S LED Panel
System
LED Color Function
PWR Green
Lights to indicate that the Switch has power.