GS-4210-Series (V2) Quick Guide
9
5. Terminal Setup
The GS-4210-8P2T2S, GS-4210-16P4C, GS-4210-24P4C and GS-4210-24PL4C
are equipped with a console interface for local switch setup and maintenance. To
congure the system, connect a serial cable to a COM port on a PC or notebook
computer and to the RJ45 type of the console port of the Managed Switch.
Managed Switch
PC / Workstation
with
Terminal Emulation Software
Serial Port
RS232 to RJ45 Cable
Console Port
RJ45
Figure 5-1: Managed Switch Console Connectivity
A terminal program is required to make the software connection to the Managed
Switch.
1. Run terminal program on the OS.
2. When the following screen appears, make sure that the COM port should be
conguredas:
zBaud:115200
zDatabits:8
zParity:None
zStopbits:1
zFlowcontrol:None
Figure 5-2 COM Port Conguration
Note
Console interface is not available for the GS-4210-8P2S and
GS-4210-48P4S.