User Manual
Table Of Contents
In-band and out-band Loop back
1. Instruct center Media Converter to issue an OAM frame to request a loop back test. Terminal return start response
OAM frame to center Media Converter.
2. Terminal Media Converter runs at loop back mode.
3. Central Media Converter send test frame and terminal Media Converter loop back the frames. Test frame can be
generated from central Media Converter’s UTP port (Out-Band) or from central Media Converter (In-Band)
automatically.
4. Center Media Converter check the loop back test result after sending all test frames
5. Instruct the central Media Converter to end loop back test.
This function provides TS-1000 Loop Back Test of Managed Media Converter. Press the “Apply” button to run Loop Back
Test and see the TS-1000 Loop Back Test Result of Managed Media Converter, also press the “Refresh” button to renew
the Web screen. The screen in Figure 4-38 appears and Table 4-14 describes the TS-1000 Loop Back Test object of
Managed Media Converter.
Figure 4-38 Remote TS-1000 Loop Back Test Web Page screen
The TS-1000 Loop Back Test Web page includes the following configurable data:
TS-1000 Loop Back Test
Send Packet Number
Allow input the number for packet send and the available options is 1 to 255. Default is
16.
Apply button
Press this button for save current configuration of Managed Media Converter.
Refresh button
Press “Refresh” button to refresh current status.
-44-