User Manual

1.5 PRODUCT SPECIFICATION
Model FT-902 FT-902S15 FT-902S35 FT-902S50 FT-905A FT-906A20 FT-906B20
Hardware Specification
Ports
1 x 10/100Base-TX port
1 x 100Base-FX port
Copper Interface RJ-45 port (Auto-MDI/MDI-X) Twisted Pair
Optic Interface SC SFP WDM
Optic Wavelength 1300nm 1310nm 1310nm 1310nm -
TX:1310
RX:1550
TX:1550
RX:1310
Max. -14 -7 -5 -0 - -8 Launch
Power(dBm)
Min. -19.0 -20 -9 -5 - -14
Receive Sensitivity -34.5 -28 -32 -34 - -31
Maximum Input power -14 -8 -5 -8 - *
Link Budget (dB) 15.5 8 23 29 - 17
Twisted-pair
10/20Mbps for Half/Full-duplex
100/200Mbps for Half/Full-duplex Speed
Fiber-optic 200Mbps for Full-Duplex
Twisted-pair
10Base-T: 2-pair UTP Cat. 3,4,5, up to 100 m
100Base-TX: 2-pair UTP Cat. 5, up to 100 m
Cable
Fiber-optic
Cable
50/125μm or 62.5/125μm multi-mode fiber cable, up to 2km.
9/125μm single-mode cable, provide long distance for 20/40/60km (vary on SFP module)
LED Indicator
y PWR,
y TP LINK/ACT, 100
y Fiber LINK/ACT
Power Consumption 3.3 Watts/ 11BTU (maximum)
Power Input DC 5V / 2A
Dimensions 94 x 70 x 26mm (W x D x H)
Standard Conformance
Standards
IEEE 802.3, 10Base-T
IEEE 802.3u, 100Base-TX
IEEE 802.3u, 100Base-FX
Emissions FCC Class A, CE Class A
Environment
Operator Environment Operating temperature: 0 to 50 Degree C; Humidity: 5~90% non-condensing
Storage Environment storage temperature: -10 to 70 Degree C; Humidity: 5~90% non-condensing
-2-