User’s Manual of FGSW-Series 
66 
Buttons 
: press this button to take effect. 
: press this button to refresh information. 
4.3.2 PoE Alive Check 
The Managed PoE+ Switch can be configured to monitor connected PD’s status in real-time via ping action. Once the PD stops 
working and without response, Managed PoE+ Switch is going to restart PoE port port power, and bring the PD back to work. It 
will greatly enhance the reliability and reduces administrator management burden. 
This page provides you how to configure PD Alive Check function as the screen in Figure 4-3-4 appears. 
Figure 4-3-4: PoE Alive Check Configuration Page Screenshot 
The page includes the following fields: 
Object  Description 
Global Settings 
•  Check Every xxx Seconds 
This column allows user to set how long system should be issue a ping request 
to PD for detecting PD is alive or dead. Check time range is from 10 seconds to 
600 seconds. 
•  Wake up After xxx Seconds 
This column allows user to set the PoE device rebooting time, due to there are 
so many kind of PoE device on the market and theyhave different rebooting 
time. This function is not a defining standard, so the PoE device on the market 
doesn’t report reboots done information to Managed PoE+ Switch, so user has 
to make sure how long the PD will be finished to boot, and then set the time 
value to this column.   