User's Manual

Table Of Contents
Users Manual of FGSW-Series
66
Buttons
: press this button to take effect.
: press this button to refresh information.
4.3.2 PoE Alive Check
The Managed PoE+ Switch can be configured to monitor connected PDs status in real-time via ping action. Once the PD stops
working and without response, Managed PoE+ Switch is going to restart PoE port port power, and bring the PD back to work. It
will greatly enhance the reliability and reduces administrator management burden.
This page provides you how to configure PD Alive Check function as the screen in Figure 4-3-4 appears.
Figure 4-3-4: PoE Alive Check Configuration Page Screenshot
The page includes the following fields:
Object Description
Global Settings
Check Every xxx Seconds
This column allows user to set how long system should be issue a ping request
to PD for detecting PD is alive or dead. Check time range is from 10 seconds to
600 seconds.
Wake up After xxx Seconds
This column allows user to set the PoE device rebooting time, due to there are
so many kind of PoE device on the market and theyhave different rebooting
time. This function is not a defining standard, so the PoE device on the market
doesn’t report reboots done information to Managed PoE+ Switch, so user has
to make sure how long the PD will be finished to boot, and then set the time
value to this column.