User's Manual
Table Of Contents
- 1. INTRODUCTION
- 2. INSTALLATION
- 3. SWITCH MANAGEMENT
- 4. WEB CONFIGURATION
- 4.1 Main Web Page
- 4.2 System
- 4.3 PoE Configuration
- 4.4 Basic Configuration
- 4.5 VLAN Configuration
- 4.6 QoS Configuration
- 4.7 ACL Configuration
- 4.8 Security
- 4.9 Advanced Features
- 4.10 Monitoring
- 5. COMMAND LINE INTERFACE
- 6. Command Line Mode
- 7. SWITCH OPERATION
- 8. Power over Ethernet Overview
- 9. TROUBLESHOOTING
- APPENDEX A: Networking Connection
- APPENDIX B: GLOSSARY
User’s Manual of FGSW-Series
177
4.10.1 MIB Counter
This page allows you to configure the MIB Counter settings for Managed PoE+ Switch as the screen in Figure 4-10-2 appears.
Figure 4-10-2: MIB Counter Configuration Page Screenshot
The page includes the following fields:
Buttons
: press this button to refresh current MIB counter information.
: press this button to clear current MIB counter information.
Object Description
• Port No. This column provides display per port list.
Receive
• Packets
This column provides displaying per port traffic in packets receive counters.
• Bytes
This column provides displaying per port traffic in bytes receive counters.
Transmit
• Packets
This column provides displaying per port traffic in packets transmit counters.
• Bytes
This column provides displaying per port traffic in bytes transmit counters.
• Action
This column provides click to select all port or specific port for refresh or clear
current MIB counter information.
• Detail
This column provides click to enter advanced per port MIB counter web page.