4.9.1.3 MST Configuration Identification
This page allows you to configure the MST Configuration Identification settings for Managed PoE+ Switch as the screen in
Figure 4-9-7 appears.
Figure 4-9-7: MST Configuration Identification Configuration Page Screenshot
The page includes the following fields:
Object Description
MST Configuration Identification Settings
Configuration Name This column provides configuring the configuration name and the available
characters is 32.
Revision Level This column provides configuring the Revision Level settings and the available
range is
0
to
65535
.
Instance ID Settings
MSTI ID (1-4094) This column provides configuring the MSTI ID settings and the available range
is
1
to
4094
.
Action This column provides selecting the Action of MSTI; the default version is Add
VID and available options are Add VID and Remove VID.
VID List (1-4094) This column provides configuring the VID List settings f MSTI; the available VID
range is
1
to
4094
.
MTSI ID Display MSTI ID information.
VID List Display VID List information.
Action
: press this button to edit specific Instance ID Settings.
: press this button to delete specific Instance ID Settings.
Button
: press this button to take effect.