User's Manual

Table Of Contents
69
Users Manual of CS-6306R
Chapter 3. Chassis Switch Management
Management Options 3.1
To set up the Chassis Switch, the user needs to configure the Chassis Switch for network management. The
Chassis Switch provides two management options: Out-of-Band management and In-Band management.
3.1.1 Out-of-Band Management
Out-of-band management is the management through Console interface.
To configure the system, connect a serial cable to a COM port on a PC or notebook computer and to serial
(console) port of the CS-6306R Chassis Switch. The console port of the Chassis Switch is DCE already, so
that you can connect the console port directly through PC without the need of Null Modem.
Figure 3-1 CS-6306R Chassis Switch Console Connection
A terminal program is required to make the software connection to the CS-6306R Chassis Switch. Putty or
Tera Term may be a good choice.
1. Run terminal program Tera Term on the OS
2. When the following screen appears, make sure that the COM port should be configured as:
Baud Rate: 9600
Data Bits: 8
Parity: None
Stop: 1
Flow Control: None