User's Manual

Table Of Contents
63
Users Manual of CS-6306R
Before connecting the other chassis switch, workstation or media converter,
1. Make sure both sides of the SFP transceiver are with the same media type, for example, 1000BASE-SX
to 1000BASE-SX, 1000BASE-LX to 1000BASE-LX.
2. Check whether the fiber-optic cable type matches the SFP transceiver model.
To connect to 1000BASE-SX SFP transceiver, use the multi-mode fiber cable with one side being
the male duplex LC connector type.
To connect to 1000BASE-LX SFP transceiver, use the single-mode fiber cable with one side being
the male duplex LC connector type.
Before connecting the other chassis switch, workstation or media converter,
1. Make sure both sides of the SFP+ transceiver are with the same media type, for example, 10GBASE-SR
to 10GBASE-SR, 10GBASE-LR to 10GBASE-LR.
2. Check whether the fiber-optic cable type matches the XFP transceiver model.
To connect to 10GBASE-SR SFP+ transceiver, use the multi-mode fiber cable with one side being
the male duplex LC connector type.
To connect to 10GBASE-LR SFP+ transceiver, use the single-mode fiber cable with one side being
the male duplex LC connector type.
Connecting the fiber cable
1. Attach the duplex LC connector on the network cable to the SFP/SFP+ transceiver.
2. Connect the other end of the cable to a device switches with SFP/SFP+ installed, fiber NIC on a
workstation or a media converter.
3. Check the LNK/ACT LED of the SFP/SFP+ slot on the front of the Chassis Switch. Ensure that the
SFP/SFP+ transceiver is operating correctly.
4. Check whether the Link mode of the SFP/SFP+ port is connecting to fiber NICs, switch or media
converter. If not, set the Link mode to “1000 Force”/“10G”.
Removing the transceiver module
1. Make sure there is no network activity by checking with the administrator. Or through the management
interface of the switch/converter (if available), disable the port in advance.
2. Remove the Fiber Optic Cable gently.
3. Turn the handle of the MGB/MTB module to the horizontal position.
4. Pull out the module gently through the handle.