User's Manual

Table Of Contents
348
Users Manual of CS-6306R
34.2.4 CFM Maintenance
34.2.4.1 Using the Loopback Function
Configuration mode: EXEC
Command Purpose
ethernet cfm loopback mdnf {string}
mdn <char_string> manf {string} man
<char_string> mepid <1-8191> mac
<AA: BB: CC: DD: EE: FF>
number <1-64>
Uses a designated MEP to conduct
loopback towards itself.
34.2.4.2 Using the Linktrace Function
Configuration mode: EXEC
Command Purpose
ethernet cfm linktrace mdnf {string}
mdn <char_string> manf {string} man
<char_string> mepid <1-8191> mac
<AA: BB: CC: DD: EE: FF>
[ttl {1-255} | fdb-only
{yes}]<char_string> manf {string}
man <char_string> mepid
<1-8191>mac <AA: BB: CC: DD
:
EE: FF>ttl <1-255>
Uses a designated MEP to conduct
loopback towards itself.
34.2.5 Configuration Example
You want to add a maintenance domain whose name is customer and hierarchy is 5, set a customer1
maintenance association for vlan1, configure the transmission interval of CCM of the maintenance
association to 1s and add an MEP whose MEPID is 2009 to physical port1.
Switch_config#ethernet cfm md mdnf string mdn customer level 5
Switch_config_cfm#ma manf string man customer1 vlan 1 ci 1s meps 1-2,2009
Switch_config_cfm#interface g0/1
Switch_config_g0/1#ethernet cfm mep add mdnf string mdn customer manf string man customer1 mepid 2009 direction
DOWN
Switch_config_g0/1#exit
Switch_config#ethernet cfm enable