User's Manual

Table Of Contents
340
Users Manual of CS-6306R
between 100 and 6000 on a 1000M
Ethernet interface and its default value is
100 in this case, while the window size
ranges between 10 and 600 on a 100M
Ethernet interface and its default value is 10
in this case.
Step7 ethernet oam link-monitor frame-seconds
{threshold {high { symbols |none} | low
{symbols}} | window symbols}
Sets the high and low thresholds of the
second event of error frame, which triggers
the link events of error frame’s second.
The threshold high parameter is used to
configure the high threshold. Its unit is signal
number. It ranges between 1 and 900 and its
default value is none.
The threshold low parameter is used to
configure the low threshold. Its unit is signal
number. It ranges between 0 and 900 and its
default value is 1.
The window parameter is used to configure
the window size of the round-query period.
Its unit is second. It ranges between 10 and
900 and its default value is 60.
Step8 ethernet oam link-monitor receive-crc
{threshold {high { symbols |none} | low
{symbols}} | window symbols}
Sets the high and low thresholds of the error
CRC frame event, which triggers the link
events of CRC checksum error.
The threshold high parameter is used to
configure the high threshold. Its unit is signal
number. It ranges between 1 and 65535 and
its default value is none.
The threshold high parameter is used to
configure the low threshold. Its unit is signal
number. It ranges between 0 and 65535 and
its default value is 1.
The window parameter is used to configure
the window size of the round-query period.
Its unit is second. It ranges between 1 and
180 and its default value is 10.