33.1.3.2 Enabling Remote OAM Loopback
The procedure to enable remote loopback on an interface is shown in the following table:
Procedure Command Purpose
Step1 config
Enters the global configuration mode.
Step2 interface intf-type intf-id
Enters the interface configuration mode.
Step3 ethernet oam remote-loopback {supported |
timeout seconds}
Configures optional loopback parameters
from the remote OAM:
The supported parameter is used to
enable an interface to support the remote
loopback of Ethernet OAM. Remote
loopback is not supported by default.
The timeout parameter is used to
configure the timeout time of remote
loopback. It ranges between 1 and 10
and its default value is 2.
Step4 exit
Exits from interface configuration mode.
Step5 exit
Exits from the global configuration mode.
Step6 ethernet oam remote-loopback {start | stop}
interface intf-type intf-id
Enables or disables remote loopback on an
interface.
The remote OAM loopback cannot be enabled on the physical interface that belongs to the aggregation
interface.
33.1.3.3 Configuring OAM Link Monitoring
You can configure the low threshold and the high threshold of OAM link monitoring.
The procedure to configure the OAM link monitoring on an interface is shown in the following table:
Procedure Command Purpose
Step1 config
Enters the global configuration mode.
Step2 interface intf-type intf-id
Enters the interface configuration mode.
Step3 ethernet oam link-monitor supported
Enables link monitoring on an interface. The
link monitoring is supported by default.
Step4 ethernet oam link-monitor symbol-period
{threshold {high { symbols |none} | low
{symbols}} | window symbols}
Sets the high and low threshold of the
periodical event of the error signal, which
triggers the error link events.
The threshold high parameter is used to
configure the high threshold. Its unit is signal
number. It ranges between 1 and 65535 and
its default value is none.
The threshold high parameter is used to
configure the low threshold. Its unit is signal
number. It ranges between 0 and 65535 and