Configuring switch S7:
The following commands are used to set the major-ring transit node, node 1:
Switch_config#mether-ring 1 domain 1
Switch_config_ring1#transit-node
Switch_config_ring1#major-ring
Switch_config_ring1#control-vlan 2
The following commands are used to set the time related parameters:
Switch_config_ring1#pre-forward-time 12
Exits from the node configuration mode:
Switch_config_ring1#quit
The following commands are used to set the transit port of node 1:
Switch_config#interface gigaEthernet 0/1
Switch_config_g0/1#mether-ring 1 domain 1 transit-port
Switch_config_g0/1#switchport mode trunk
Switch_config_g0/1#quit
Switch_config#interface gigaEthernet 0/2
Switch_config_g0/2#mether-ring 1 domain 1 transit-port
Switch_config_g0/2#switchport mode trunk
Switch_config_g0/2#quit
The following commands are used to set the sub-ring edge node, node 4:
Switch_config#mether-ring 4 domain 1
Switch_config_ring4#edge-node
Switch_config_ring4#sub-ring
This can be omitted
Switch_config_ring4#control-vlan 2
The following commands are used to set the time related parameters:
Switch_config_ring4#pre-forward-time 12
Exits from the node configuration mode:
Switch_config_ring4#quit
The following commands are used to set the common port and edge port of node 4:
Switch_config#interface gigaEthernet 0/2
Switch_config_g0/2#mether-ring 4 domain 1 common-port
Switch_config_g0/2#quit
Switch_config#interface gigaEthernet 0/3
Switch_config_g0/3#mether-ring 4 domain 1 edge-port
Switch_config_g0/3#switchport mode trunk
Switch_config_g0/3#quit