User's Manual

Table Of Contents
258
Users Manual of CS-6306R
23.1.3.2 Configuring holdtime
You can control the timeout time of transmitting the LLDP message through modifying holdtime:
Run the following command in global configuration mode to configure holdtime of LLDP:
Command Purpose
lldpholdtimetime
Configures the timeout time of LLDP.
nolldpholdtime
Resumes the timeout time to the
default value, 120 seconds.
23.1.3.3 Configuring timer
You can control the interval of the switch to transmit message by configuring the timer of LLDP.
Run the following command in global configuration mode to configure timer of LLDP:
Command Purpose
lldptimertime
Configures the interval of message transmission of LLDP.
no lldptimer
Resumes the default interval, that is, 30 seconds.
23.1.3.4 Configuring reinit
You can control the interval of the switch to continuously transmit two messages by configuring reinit of LLDP.
Run the following command in global configuration mode to configure reinit of LLDP:
Comman
d
Purpose
lldpreinit
time
Configures the interval of LLDP to continuously transmit message.
no
lldpreinit
Resumes the default interval of continuously transmitting message;
the default interval value is two seconds.
23.1.3.5 Configuring To-Be-Sent TLV
You can choose TLV which requires to be sent by configuring tlv-select of LLDP. By default, all TLVs are
transmitted.
Run the following commands in global configuration mode to add or delete tlv of LLDP:
Command Purpose
lldptlv-selecttlv-type
Tlvs or tlv-types which needs to be added include:
macphy-confg
management-address
port-description
port-vlan
system-capabilities
system-description
system-name