Management Module for CS-6306R CS6-MCU Standard Chassis Switch Module for CS-6306R CS6-S24S8X/CS6-S24T8X/CS6-S48S CS6-S48T/CS6-S16X/CS6-S4Q/CS6-S24T24S Quick Installation Guide
Table of Contents 1. Introduction................................................................................................ 3 2. Hardware Installation................................................................................... 4 2.1 Desktop Installation.............................................................................. 4 2.2 Module Installation............................................................................... 4 3. Management Module Description............................
1. Introduction PLANET CS-6306R is a 6-slot,19-inch, 9U Rack-mountable Chassis, supporting various types of Chassis Switch modules. It can seamlessly support network interfaces from 100Mbps and 1000Mbps to 10Gbps or 40Gbps Ethernet.
2. Hardware Installation 2.1 Desktop Installation The Chassis Switch is very heavy and weighs about 30kg when fully configured. Please carry and install it by two people to avoid injury. To install the CS-6306R on a desktop or shelf, simply complete the following steps: Step 1 Choose a good workbench. Step 2 Verify that the workbench is strong enough to support the CS-6306R’s fully configured weight.
6 5 4 3 2 1 Figure 2-1 CS-6306R Front Panel Step 1 Power down the CS-6306R before installing all the modules. Hot-swapping of a module is recommended when the CS-6306R is in operation. Step 2 Ensure proper grounding of the CS-6306R. Step 3 To remove a module, loosen counterclockwise the screws on the right and left. Then, the right lever and the left lever should be lifted upward at the same time and pull the module out.
Step 4 To install a module, make sure it is aligned with the rail and then slide it into the slot. The right lever and the left lever should be lightly pushed down at the same time. Lastly, get the two screws fastened to finish putting the module in place.
3. Management Module Description 3.1 CS6-MCU 3.1.1 CS6-MCU Specifications Product CS6-MCU Hardware Specifications Switching Capacity 2.56Tbps Forwarding Rate 1920 Mpps LED 1 1 1 1 1 1 Standards Compliance IEEE 802.3az green Efficient Ethernet IEEE 802.1x authentication Operating Temperature 0°C ~ 40°C Operating Humidity 10%~90% (non-condensing) Dimensions (WxDxH) 400 x 300 x 41 mm Weight (empty) 2458g CS-6306R Allowed Module Slots Slots 5 and 6 x x x x x x SYS LED – Green.
zz Console Port The console port is an RJ45 type, RS-232 male serial port connector. It is an interface for connecting a terminal directly. Through the console port, it provides rich diagnostic information including IP address setting, factory reset, port management, link status and system setting. Users can use the attached RS-232 cable in the package and connect to the console port on the device.
Red Lights to indicate that the power supply of the system is abnormal. Off If the red indicator is off, the power supply of the system is normal. Green Lights to indicate that the MCU is in the master control state. Off If the green indicator is off, the MCU is in a non-master state.
4. Standard Chassis Switch Module Description 4.1 CS6-S24S8X 4.1.1 CS6-S24S8X Specifications Product CS6-S24S8X Hardware Specifications SFP/mini-GBIC Slots 24 x 100/1000BASE-SX/LX SFP slots SFP+/mini-GBIC Slots 8 x 1/10GBASE-SR/LR SFP+ slots Switch Fabric 208Gbps Throughput 154Mpps@64bytes LED 1 x Alarm LED – Red. 1 x SYS LED – Green. LINK/ACT LED – Green. Standards Compliance IEEE 802.3u 100BASE-FX IEEE 802.3z Gigabit SX/LX IEEE 802.
Provides one debugging serial port for single board debugging, which is not open for the clients. LEDs The front panel LEDs indicate instant status of port links, data activity, system operation and system power. The system helps to monitor and troubleshoot when needed. Figure 4-2 shows the front panel of the Standard Chassis Switch Module.
4.2 CS6-S24T8X 4.2.1 CS6-S24T8X Specifications Product CS6-S24T8X Hardware Specifications Copper Ports 24 x 10/100/1000BASE-T RJ45 ports SFP+/mini-GBIC Slots 8 x 1/10GBASE-SR/LR SFP+ slots Switch Fabric 208Gbps Throughput 154Mpps@64bytes LED 1 x Alarm LED – Red. 1 x SYS LED – Green. LINK/ACT LED – Green. Standards Compliance IEEE IEEE IEEE IEEE IEEE Dimensions (WxDxH) 400 x 300 x 41 mm Weight (empty) 2800g CS-6306R Allowed Module Slots Slots 1, 2, 3 and 4 802.3 10BASE-T 802.
Provides one debugging serial port for single board debugging, which is not open for the clients. LEDs The front panel LEDs indicate instant status of port links, data activity, system operation and system power. The system helps to monitor and troubleshoot when needed. Figure 4-4 shows the front panel of the Standard Chassis Switch Module.
4.3 CS6-S48S 4.3.1 CS6-S48S Specifications Product CS6-S48S Hardware Specifications SFP/mini-GBIC Slots 48 x 100/1000BASE-SX/LX SFP slots Switch Fabric 96Gbps Throughput 71Mpps@64bytes LED 1 x Alarm LED – Red. 1 x SYS LED – Green. LINK/ACT LED – Green. Standards Compliance IEEE 802.3u 100BASE-FX IEEE 802.3z Gigabit SX/LX Dimensions (WxDxH) 400 x 300 x 41 mm Weight (empty) 2869g CS-6306R Allowed Module Slots Slots 1, 2, 3 and 4 4.3.
CS6-S48S LED Indication 38 40 42 44 46 48 CS6-S48S Alarm SYS Console 37 39 41 43 45 47 9600, N, 8, 1 Figure 4-6 CS6-S48S LED Panel zz System LED ALM SYS Color Function Green Lights to indicate that an alarm occurs in the single board. Off To indicate the Chassis Switch Module runs normally. Green If the green indicator flickers, the module runs normally.
4.4 CS6-S48T 4.4.1 CS6-S48T Specifications Product CS6-S48T Hardware Specifications Copper Ports 48 x 10/100/1000BASE-T RJ45 ports Switch Fabric 96Gbps Throughput 71Mpps@64bytes LED 1 x Alarm LED – Red. 1 x SYS LED – Green. LINK/ACT LED – Green. IEEE 802.3 10BASE-T IEEE 802.3u 100BASE-TX IEEE 802.3ab Gigabit 1000T 802.3z Gigabit SX/LX Dimensions (WxDxH) 400 x 300 x 41 mm Weight (empty) 2896g CS-6306R Allowed Module Slots Slots 1, 2, 3 and 4 4.4.
CS6-S48T LED Indication 38 40 42 44 46 48 CS6-S48T Alarm SYS Console 37 39 41 43 45 47 9600, N, 8, 1 Figure 4-8 CS6-S48T LED Panel zz System LED ALM SYS Color Function Green Lights to indicate that an alarm occurs in the single board Off To indicate the Chassis Switch Module runs normally. Green If the green indicator flickers, the module runs normally.
4.5 CS6-S24T24S 4.5.1 CS6-S24T24S Specifications Product CS6-S24T24S Hardware Specifications Copper Ports 24 x 10/100/1000BASE-T RJ45 ports SFP/mini-GBIC Slots 24 x 1000BASE-SX/LX SFP slots Switch Fabric 96Gbps Throughput 71Mpps@64bytes LED 1 x Alarm LED – Red. 1 x SYS LED – Green. LINK/ACT LED – Green. Standards Compliance IEEE IEEE IEEE IEEE Dimensions (WxDxH) 400 x 300 x 41 mm Weight KG (empty) 2860g CS-6306R Allowed Module Slots Slots 1, 2, 3 and 4 802.3 10BASE-T 802.
LEDs The front panel LEDs indicate instant status of port links and data activity. It helps to monitor and troubleshoot when needed. Figure 4-10 shows the front panel of the Standard Chassis Switch Module.
4.6 CS6-S16X 4.6.1 CS6-S16X Specifications Product CS6-S16X Hardware Specifications SFP+/mini-GBIC Slots 16 x 1G/10GBASE-X SFP+ slots Switch Fabric 320Gbps Throughput 238Mpps@64Bytes LED 1 x Alarm LED – Red. 1 x SYS LED – Green. LINK/ACT LED – Green. Standards Compliance IEEE 802.3z Gigabit SX/LX IEEE 802.3ae 10 Gigabit Ethernet Dimensions (WxDxH) 400 x 300 x 41 mm Weight (empty) 2424g CS-6306R Allowed Module Slots Slots 1, 2, 3 and 4 4.6.
CS6-S16X LED Indication CS6-S16X 10GBASE-X SFP+ T14 T15 T16 T4 T8 T3 T7 T11 T15 T2 T6 T10 T14 Alarm T12 T16 T1 T5 T9 T13 SYS Console 9600, N, 8, 1 Figure 4-12 CS6-S16X LED Panel zz System LED ALM SYS Color Function Green Lights to indicate that an alarm occurs in the single board Off To indicate the Chassis Switch Module runs normally. Green If the green indicator flickers, the module runs normally.
4.7 CS6-S4Q 4.7.1 CS6-S4Q Specifications Product CS6-S4Q Hardware Specifications QSFP+ Slots 4 x 40GBASE-X QSFP+ slot Switch Fabric 320Gbps Throughput 238Mpps@64Bytes LED 1 x Alarm LED – Red. 1 x SYS LED – Green. LINK/ACT LED – Green. Standards Compliance IEEE 802.3ba 40 Gigabit Ethernet Dimensions (WxDxH) 400 x 300 x 41 mm Weight (empty) 2800g CS-6306R Allowed Module Slots Slots 1, 2, 3 and 4 4.7.
CS6-S4Q LED Indication 1 2 3 4 Alarm SYS QTG4 Console 9600, N, 8, 1 Figure 4-14 CS6-S4Q LED Panel zz System LED ALM SYS Color Function Green Lights to indicate that an alarm occurs in the single board Off To indicate the Chassis Switch Module runs normally. Green If the green indicator flickers, the module runs normally. zz 40G QSFP QSFT+ Interfaces LED LNK/ ACT Color Green Off Function Lights to indicate the link through that port is successfully established with speed 40GMbps.
Customer Support Thank you for purchasing PLANET products. You can browse our online FAQ resource at the PLANET Web site first to check if it could solve your issue. If you need more support information, please contact PLANET support team. PLANET online FAQs: http://www.planet.com.tw/en/support/faq.php?type=1 Support team mail address: support@planet.com.tw CS6-Sx Series User’s Manual https://www.planet.com.tw/en/support/download.