Industrial Renewable Energy 4-Port 10/100/1000T
802.3at PoE+ Managed Ethernet Switch
BSP-360
80
Object Description
request to PD for detecting whether PD is alive or dead. Interval time
range is from 10 seconds to 300 seconds.
Retry Count (1~5)
This column allows user to set how many times system wants to retry ping
to PD. For example, if we set count 2, the meaning is that if system retry
ping to the PD and the PD doesn’t response continuously, the PoE port
will be reset.
Action
Allows user to set which action will be apply if the PD is without any
response. The Renewable Energy Switch offers 3 actions as follows:
PD Reboot: It means system will reset the PoE port that is connected to
the PD.
PD Reboot & Alarm: It means system will reset the PoE port and issue an
alarm message via Syslog,
Alarm: It means system will issue an alarm message via Syslog.
Reboot Time (30~180s)
This column allows user to set the PoE device rebooting time. As there are
so many kinds of PoE devices on the market, they have different rebooting
times.
The PD Alive-check is not a defining standard, so the PoE device on the
market doesn’t report reboots done information to the Ultra PoE Managed
Injector Hub. So user has to make sure how long the PD will be finished to
boot, and then set the time value to this column.
System is going to check the PD again according to the reboot time. If you
cannot make sure precise booting time, we suggest you set it longer.
button
Click to apply changes.
button
Refreshes the Web page and the current configuration if user doesn’t save
it.
Table 4-6-5: Descriptions of the PoE Schedule Configuration Objects