4.6.4 PoE Alive Check Configuration
The Renewable Energy Switch can be configured to monitor connected PD’s status in real-time via ping
action. Once the PD stops working and without response, the Renewable Energy Switch are going to restart
PoE port power, and bring the PD back to work. It will greatly enhance the reliability and reduces administrator
management burden.
This page provides you with how to configure PD Alive Check as the screen in Figure 4-6-6 appears.
Figure 4-6-6: PD Alive Check Configuration Web Page Screen
Object Description
Mode
Allows user to enable or disable per port PD Alive Check function. All ports
are disabled as default value.
Remote PD IP Address
This column allows user to set PoE device IP address here for system
making ping to the PoE device. Please note that the PD’s IP address must
be set to the same network segment as the Renewable Energy Switch.
Interval Time (10~300s)
This column allows user to set how long system should issue a ping