Object Description
When the battery voltage is less than the value for low‐voltage
disconnection, the controller will not supply to the load so as to protect
the battery from over‐discharge.
Low Voltage Reconnection
DC 24.8V (23.0~27.0V)
When the battery is under the condition of low voltage disconnection, if
the battery voltage is recovered and higher than the value for low voltage
reconnection, the low‐voltage circuit disconnection will be lifted and the
connection is restored.
Low Voltage Cut-Off
Protection
Off Disable this function.
Log & Trap
When the battery capacity is lower than 20% that
send log and SNMP trap to server.
Log & Trap & Cut
When the battery capacity is lower than 20% that
send log and SNMP trap to server, and power off
the low priority port.
Set Solar to Default
Press this button to reset FCV, ACV, LVD and LVR setting to default
value.
Reset
Press this button to revert to previously saved values.
Apply
Press this button to take effect.
Table 4-5-1: Descriptions of the Battery Management Objects