Step 4. Connect 802.3af/802.3at PoE Device
Connect the PoE devices to ports 1~ 4 on the BSP-360.
Check the PoE-in-Use LED. If the network devices such as PoE camera and PoE wireless AP are powered,
the PoE-in-use LED will turn ON and Link/Act LED will blink for a successful connection or data receiving.
Please use Cat5/5e or above cable and the maximum distance should within
100
meters.
If the Network devices are installed outdoors
, please consider to install a lightening
arrestor to protect the network device and the BSP-360.
Step 5. Wiring the DC Outputs
Please follow the steps below to insert the power wires for DC power required equipment.
Please find the terminal block connector with two DC power outputs shown below:
V1+
V2+
V1-
V2-
Insert the Positive and Negative DC wires into the V+ and V- terminals, respectively; Terminals 1 and 3 for
Power 1, and Terminals 2 and 4 for Power 2.
Connect the other points of DC power wires to the power devices. Tighten the wire-clamp screws for
preventing the wires from loosening.