User Manual

Industrial Renewable Energy 4-Port 10/100/1000T
802.3at PoE+ Managed Ethernet Switch
BSP-360
21
The wire gauge for the terminal block should be in the range from 14 to 24 AWG.
DO Connectors
Level 0: -24V~2.1V (±0.1V)
Level 1: 2.1V~24V (±0.1V)
2.1.4 Wiring the Fault Alarm Contact
The fault alarm contacts are in the middle (3 & 4) of the terminal block connector as the picture shows below.
Inserting the wires, the Renewable Energy Switch will detect the fault status of the power failure, or port link
failure (available for managed model). The following illustration shows an application example for wiring the
fault alarm contacts
Insert the wires into the fault alarm contacts
1. The wire gauge for the terminal block should be in the range of 14 ~ 24 AWG.
2. When performing any of the procedures like inserting the wires or tightening the wire-clamp
screws, make sure the power is OFF to prevent from getting an electric shock.