User's Manual

The sensitivity parameter is used to
dene the point at which the Eclipse-
blade Zero.B registers that a ball is in the
breech of the marker.
Scroll through the Main Menu until the
SENSTIV parameter is displayed.
The signal from the breech sensor is
represented as a percentage value and
this value is shown at the top right of the
display. As an object passes in front of
the breech sensor (or between the trans-
mitter and receiver in the case of a break
beam sensor) then this value increases,
as the object is removed then the value
decreases. The breech sensor value is
also represented by a graphical bar on
the right-hand side of the screen.
The Sensitivity parameter is shown at the
bottom right of the display and this is also
expressed as a percentage value. When
the breech sensor value is less than the
Sensitivity then the Eclipseblade Zero.B
considers that the breech is empty. When
the breech sensor value is greater than
the Sensitivity then the Eclipseblade
Zero.B considers that the breech is full,
i.e. that a paintball is present.
To determine whether or not the breech
sensor is working correctly, simply open
the breech by retracting the bolt and
watch the breech sensor value drop.
Close the bolt and the breech sensor
value will rise.
THE SENSITIVITY PARAMETER Setting the
sensitivity Paramater
The factory setting for the Sensitivity
parameter should be ne for most setups
and paint, however you may have to
make adjustments to this parameter
if the breech sensor is not detecting
paintballs.The procedure for doing this is
as follows:
1. Retract the bolt and ensure that noth-
ing is in the breech. Note the breech sen-
sor value in the top right of the display.
2. Drop a paintball into the breech. In
the case of multi-coloured paintballs,
ensure that the darker colour is facing
the breech sensor (not applicable for
break beam sensors). Note the breech
sensor value.
3. Set the Sensitivity parameter to a
value approximately half way between
the two recorded breech sensor values.
To adjust the parameter, press SELECT
to enter the edit mode. Press and release
the Raise pushbutton to increase the pa-
rameter value. Press and hold the Raise
pushbutton to increase the parameter
value more rapidly. Press and release the
Lower pushbutton to decrease the pa-
rameter value. Press and hold the Lower
pushbutton to decrease the parameter
value more rapidly.
Break Beam If Fitted Break Beam If Fitted
Using Zero.B
12
Using Zero.B
13