User's Manual
Scroll through the SET-UP Menu until
the TIMING option is displayed and then
press Select. This will display SEAR ON
the rst parameter on the TIMING Menu.
Press the Lower pushbutton to scroll
down through each of the options on
the TIMING Menu. Once the last option
has been displayed, pressing the Lower
pushbutton will cause the rst option to
be displayed.
Press the Raise pushbutton to scroll
up through each of the options on the
TIMING Menu. Once the rst option
has been displayed, pressing the Raise
pushbutton will cause the last option to
be displayed.
Press the Select pushbutton to select the
displayed option.
Selecting BACK will return the display to
the SET-UP Menu.
THE TIMING MENU
Scroll through the TIMING Menu until
the Sear Solenoid On Time (SEAR ON)
parameter is displayed.
The current value of the Sear Solenoid
On Time (SEAR ON) is displayed in
milliseconds on the right hand side of the
display.
Press the Select pushbutton to enter the
edit function and the edit indicator will
appear on the display.
Press and release the Raise pushbutton
to increase the Sear Solenoid On Time
(SEAR ON) in 0.1 millisecond incre-
ments. Press and hold the Raise push-
button to increase the Sear Solenoid On
Time (SEAR ON) more rapidly.
Press and release the Lower pushbutton
to decrease the Sear Solenoid On Time
(SEAR ON) in 0.1 millisecond incre-
ments. Press and hold the Lower push-
button to decrease the Sear Solenoid
On Time (SEAR ON) more rapidly.
Press Select to save the Sear Solenoid
On Time (SEAR ON) and the edit indica-
tor will disappear from the display to indi-
cate that the value has been accepted.
SEAR SOLENOID ON TIME
Standard
Edit Indicator
Advanced Set-Up
24
Advanced Set-Up
25