User's Manual

6. Adjust the BAND LO parameter so that when the trigger is
fully released the bar settles beneath the indicator on the left
hand side of the screen
(SEE pAGE 46).
7. Set the MAGNET RETURN STRENGTH SCREW and the Micro
Switch Activation Screw as required, making both the spring
tension and the return force as strong as possible without

Optional (only if TT had been selected in Debounce
parameter):
8. Select the TT TOL parameter. With the gun gassed up

the marker to bounce by pulling the trigger very slowly. If
the marker bounces, then reduce the
TT TOL value until it no longer does so.
If the marker does not bounce then
increase the TT TOL value until it starts to
bounce and then reduce it again until the
bouncing stops.
Whilst this set up process should
completely eliminate bounce, it may result
in a trigger pull that is not ideally suited to
the user, in which case it will be necessary
to make adjustments to the trigger and
then modify the Trigger Filter parameters
accordingly.
THE TRAINING pARAmETER
(TRAININ)
The TRAININ parameter is used to select Training Mode.
In Training Mode the Etek STAR Frame will function
exactly the same as normal but with two important
differences:-
1. The solenoid valve is under-driven so that the rammer
only moves a small amount and does not strike the

wasting air and generating lots of noise.
2. The BBSS is overridden so that the Etek STAR
Frame can cycle without paint. The centre of the BBSS
indicator changes to a ‘T’ to indicate that Training Mode
is enabled.
The Training parameter choices are as follows:-
> OFF:
Training Mode is disabled and the Etek STAR
Frame functions normally.
> ON:
Training Mode is enabled.
> CANCEL:
Cancel editing and leave the parameter
unchanged.
NOTE: THE FASTEST WAY TO SHOOT AN ETEk STAR
FRAmE IS TO WALk THE TRIGGER WITH TWO OR mORE
FINGERS. FEATHERING (NOT FULLY RELEASING)
THE TRIGGER WILL CAUSE THE FILTERING SYSTEm
TO REDUCE THE RATE OF FIRE DOWN IN ORDER TO
ELImINATE WHAT IT pERCEIvES AS TRIGGER bOUNCE.
47.
ADvANCED SET-Up