User's Manual
THE bAND LOW pARAmETER
(bAND LO)
The BAND LO parameter is only available if OPTO has
been selected in the HARDWARE menu. BAND LO
the point at which the trigger is considered released and
is adjustable between 1% and 49% in 1% increments.
bASIC TRIGGER FILTER
SET-Up
95% of trigger bounce problems can be eliminated by
DEBOUNCE
choices (LEVEL
1-9). In attempting to eliminate trigger bounce it is
DEBOUNCE
choices before
ADvANCED TRIGGER FILTER
SET-Up
In order to optimize the Trigger Filters it is necessary to
have the BAND HI parameter set as high as possible and
the BAND LO parameter set as low as possible:
1. Select the BAND HI parameter. Observe that the graphical
bar rises and falls as the trigger is pulled and released. The
actual value of the graphical bar is displayed in the top right of
the display.
2. Set the REAR STOP TRIGGER SCREW as required, ensuring
that the bar is as close to 100% as possible when the trigger
is fully depressed against the set screw. It is advisable to
allow for some extra travel in the trigger pull once the bar has
reached its maximum value.
3. Adjust the BAND HI parameter so that when the trigger is
fully depressed the bar settles above the indicator on the left
hand side of the screen
(SEE pAGE 45).
4. Select the BAND LO parameter. Observe that the graphical
bar rises and falls as the trigger is pulled and released. The
actual value of the graphical bar is displayed in the top right of
the display.
5. Set the FRONT STOP TRIGGER SCREW as required, ensuring
that the bar is as close to 0% as possible when the trigger
is fully released against the set screw. It is advisable to allow
for some extra travel in the trigger release once the bar has
reached its minimum value.
46.
ADvANCED SET-Up