User's Manual
THE DEbOUNCE pARAmETER
(DbOUNCE)
This parameter is used to combat any trigger bounce
that might occur in the Etek STAR Frame.
This parameter can be set to the following choices:-
> TT:
The Trigger Transition Filter is used to remove
trigger bounce.
> LEvEL 9:
> LEvEL1:
> CANCEL:
Cancel editing and leave the parameter
unchanged.
THE EmpTY bREECH TImE
pARAmETER (EmpTY)
In order for the BBSS
detect that the bolt is fully retracted and the breech is
empty, and then detect that a paintball is loaded into the
Slots or holes in some third party bolts can fool the BBSS
and so this parameter is used to specify a minimum time
that the breech must be empty. The parameter can be
set between 1.0 and 20.0ms in 0.5ms increments.