RESET
FACTORY RESET
It is important that the 170R is set-up as per factory standards before
use. To restore to factory settings, follow these steps.
FIG-1
1
Press and hold the tournament lock button (see page 32) for 2
seconds to reset all control parameters.
2
Using the 1/8 hex key
A
turn the inline regulator screw
B
2 turns clockwise from its fully screwed-out position.
1
DO NOT turn the adjuster screw in too far. This will prevent the
170R from ring.