Manual

Theseparametersallrelatetothecontrolofthesolenoidvalve.
TheDWELLparametersetstheamountoftimethatthesolenoidisenergizedandthereforetheamountofgasthatisreleased
witheachshotoftheGSL.Settingthisparametertoolowwillresultinlowvelocityshotsand/orexcessiveshottoshotvelocity
fluctuations.SettingtheparametertoohighwillsimplywastegasandmaketheGSLlouder.TheDWELLcanbesetbetween0.0
and30.0milliseconds.ThefactorydefaultsettingcannormallybereducedafterafewthousandshotsastheGSL‘beds-in’.
“Firstshotdropoff”isareductioninvelocityofthefirstshotfiredafteranextendedperiodofnotfiringandiscausedbythe
stictionbetweendynamico-ringsandthesurfacesthattheyareincontactwith.Inordertocompensateforfirstshotdrop-off
thisparametercanbesettoaddextratimetotheDWELLparameterforthefirstshot.Thisparametercanbesetbetween0.0
and5.0milliseconds.
ThetimethathastoelapsebeforetheFSDCOMPisappliedtoashotfollowingapreviousshot.Thisparametercanbeset
between00:00and04:00minutes.
TiMing MEnU
DWELL ParaMETEr
FsD CoMP ParaMETEr
FsD DLY ParaMETEr
aDVanCED sETUP 33