Manual
TheGSLprovidestheuserwiththeoptiontouseeitheramicro-
switchoranOPTOsensor(defaultOPTO)asthemeansfordetecting
triggerpulls.Beforeyoubegintoadjustandsetyourtrigger,you
mustfirstselectthemethodoftriggerdetectionthatyouwishto
usebyenteringthemainmenuandmakingyourselectionfromthe
hardwaremenu(seepage37).
Therearefiveadjustmentpointsonthetrigger–thefrontstopscrew,
therearstopscrew,themagnetreturnstrengthscrew,themicro-
switchactivationscrewandthespringreturnstrengthscrew.
Figure7AKey
-Triggerleafspring
-Springreturnstrengthscrew
-Triggerpinretainingscrew
-Frontstopscrew
-Magnetreturnstrengthscrew
-Micro-switchactivationscrew
-Rearstopscrew
-OPTOsensoractivationprong
Thefrontstopscrewisusedtosettheamountoftriggertravel
priortothemarkerfiring.Turnthisscrewclockwisetoreducethe
amountoftravel.Donotturnthescrewtoofarorthetriggerwillbe
pushedpastthefiringpointandthemarkerwillnotfire.Turnthis
screwcounter-clockwisetoincreasetheamountoftriggertravel
(SEE
FIGURE7B)
.
Therearstopscrewisusedtosettheamountoftravelafterthe
markerhasfired.Turnthisscrewclockwisetoreducetheamountof
travel.Donotturnthescrewtoofarorthetriggerwillbeprevented
fromreachingitsfiringpointandthemarkerwillnotwork.Turnthis
screwcounter-clockwisetoincreasetheamountoftravel
(SEEFIGURE
7C)
.
A
B
C
D
E
F
G
H
TriggEr aDJUsTMEnT
C
D
E
F
G
H
B
A
FIG7A
FIG7B
FIG7C
C
D
E
F
G
H
B
A
12 Using THE gsL