Manual

FIG-1
11
GEO:CS1
QUICK START
SOLENOID FLOW RESTRICTOR (SFR)
FIG-1
The Solenoid Flow Restrictor (SFR)
A
controls the exhaust ow from
the bolt through the solenoid. Adjusting the SFR will change the speed
of the bolt’s forward stroke.
Use a 1/8 hex key
B
and turn clockwise to decrease the ow
(reducing the speed of the bolt) or counter-clockwise to increase the
ow (increasing the speed of the bolt).
Minimum ow (fully clockwise) will improve the smoothness of the
ring cycle but will lower the cycling rate.
Maximum ow (fully counter-clockwise) will reduce the smoothness of
the ring cycle but increase the cycling rate.
The SFR ow rate can be set anywhere between maximum and
minimum ow.
1
ALWAYS chronograph your marker once any changes have
been made. Changes to the SFR ow can directly aect the
velocity of the paintballs.
1
B
A
HEX
1/8
WARNING!
Setting the ow restrictor too low (especially in extreme weather conditions) may
result in: low velocity, inconsistent velocity or preventing the bolt from cycling.
If this occurs, increase the SFR ow setting.
WARNING
+