Manual

SFR & BLANKING PLUG
THE STAGES BELOW ON SFR MAINTENANCE DO NOT
REQUIRE THE FRAME TO BE REMOVED, AND CAN
BE FOLLOWED FOR SFR REMOVAL/ BLANKING PLUG
INSTALLATION.
Using a small hex key push the SFR body out of the left
side of the frame
(SEE FIGURE 23I).
Inspect and clean the SFR body and o-rings, making
sure the hole through the centre of the SFR body is free
of paint or debris
(SEE FIGURE 23J).
Lastly make sure the pocket in the frame that houses
the SFR and the exhaust port below are clean
(SEE
FIGURE 23K)
.
Next, insert the SFR body into the frame as shown in
FIGURE 23L. Make sure the dial sits flush with the
surface of the frame
(SEE FIGURE 23M).
THE LAST STAGE OF MAINTENANCE REQUIRES THE
FRAME TO BE REMOVED. IT IS ONLY NEED IF THE SFR
IS HAVING LITTLE OR NO EFFECT.
In the top of the frame locate and remove the SFR seal
(SEE FIGURE 23N). Inspect and clean the seal,
replacing if damaged or heavily worn.
Re insert the SFR seal into the top of the frame, making
sure the contoured face is exposed
(SEE FIGURE
23O).
FIG 23M
FIG 23N
FIG 23O
FIG 23J
FIG 23I
FIG 23L
FIG 23K
WARNING: IF YOU ARE AT ALL UNSURE AT
PERFORMING THE MAINTENANCE PROCEDURE
PLEASE CONTACT YOUR NEAREST ECLIPSE SERVICE
CENTRE. (SEE PAGE 75)