Manual

CLEANING THE INLINE
REGULATOR
Disconnect the macroline hosing from your inline
regulator allowing it to be unscrewed from the Front
Regulator Mount (FRM)
(See Figure 17A). Inspect the
o-ring at the top of the threads on the FRM for damage.
Replace and re-lubricate as necessary.
1
Turn the inline regulator upside down and carefully
unscrew the bottom section from the top section
(See
Figure 17B)
.
Tip both the piston and spring out of the top of the
inline regulator
(See Figure 17C).
Insert a 1/8” hex key into the adjuster screw in the
bottom section of the inline regulator, turn the adjuster
screw clockwise through the top of the inline regulator
bottom
(See Figure 17D), and pull out of the inline
regulator bottom when it will no longer turn upwards.
2
Thoroughly clean the 011 NBR70 o-rings that sit on the
outside of the adjuster assembly, then re-lubricate with
Eclipse Grease
(See Overleaf Figure 17E).
1
1
If any o-rings are damaged then replace them. Extra o-rings are
available in parts kits available at www.planeteclipse.com
2
The adjuster screw can only be removed by turning it upwards
through the bottom section of the inline regulator. The regulator will
be damaged if the adjuster screw is removed incorrectly.
F IG 17A
F IG 17b
F IG 17C
F IG 17D
DE-GAS YOUR MARKER, DISCHARGING ANY
STORED GAS IN A SAFE DIRECTION, AND REMOVE
THE BARREL, LOADER, AIR SYSTEM AND ANY
PAINTBALLS TO MAKE THE MARKER EASIER AND
SAFER TO WORK ON.
WARNING
54.