Manual

62 GEO3.5 MANUAL
SYMPTOM POSSIBLE CAUSE SOLUTION
The GEO3.5 does not re
The micro-switch is not being activated Adjust the micro-switch activation screw accordingly
The micro-switch is damaged
Replace the circuit board
The PCB is damaged
The solenoid valve is damaged
Replace the solenoid valve
The solenoid valve wires are damaged
The GEO3.5 does not cycle fully
The bolt assembly is dirty or incorrectly lubricated
Clean, re-lubricate and replace the o-rings on the
bolt as necessary
The Dwell parameter is set too low Increase the Dwell parameter
A sticky or faulty poppet in the solenoid manifold Check the poppet, clean and replace as necessary
The GEO3.5 is inconsistent
The Dwell parameter is set too low Increase the Dwell parameter
The Solenoid Flow Restrictor (SFR) is set too low Increase the ow through the SFR
Using poor quality paintballs Use better quality paintballs
A poor paintball to barrel bore match Use a better paintball to barrel bore size match
The inline regulator is supercharging Strip and clean inline regulator
Dirty body lter Strip and clean the body lter
Poor / inconsistent air supply into POPS Use a good quality pre-set air system
The GEO3.5 is inefcient The Dwell is excessively high Reduce the Dwell
The GEO3.5 has low rate of re
The Solenoid Flow Restrictor is set too low Increase the amount of ow on the SFR
The force setting on the loader is too low Adjust the loader force feed setting